From pressure
readings to lift.

An AF1300 wind tunnel study using 63 pressure datasets to estimate sectional lift, investigate changes in loading and understand how measurement choices affect the conclusion.

My contribution
Data processing, integration and interpretation
Tools & methods
Excel · pressure coefficients · trapezoidal integration
Context
University of Hertfordshire
Fluid Mechanics laboratory
The wind tunnel's transparent test section, aerofoil and pressure tapping tubes connected to the pressure measurement panel.
The laboratory setup: an aerofoil in the test section, with surface pressure tappings connected to the measurement system.

What can the pressure data tell us?

The task was to turn surface pressure measurements into pressure distributions and sectional lift estimates, then assess what those results could say about a small UAV application. The available workbook contained 21 pressure records at each of three fan settings: 30%, 60% and 90%.

The analysis also needed to account for imperfect data. One channel was recorded as zero, the tunnel-static pressure offset was unavailable, and the supplied surface labels produced an unexpected lift sign.

Make the calculation traceable.

Check the measurements

I matched pressure columns to the supplied tap positions, normalised the chord stations and investigated tap 9, which was zero wherever recorded.

Calculate the loading

I normalised the pressure readings by dynamic pressure, interpolated both surfaces onto shared chord stations and calculated the pressure difference.

ΔCp = Cp,lower − Cp,upper

Integrate and challenge

I used trapezoidal integration and an incidence projection to estimate sectional lift. I then checked how the tap treatment, chord-end assumptions and surface convention changed the result.

A change in the pressure distribution.

At the 60% fan setting, the room-referenced coefficient at tap 2 changed from −5.99 at 14.1° to −2.65 at 16.1°. The reduction in suction and the flatter trace are consistent with a change in loading or separation. Without flow visualisation, they do not locate separation directly.

Room-referenced pressure coefficient against chord position at 14.1 and 16.1 degrees. The leading-edge suction magnitude on the surface labelled lower reduces from about 5.99 to 2.65; tap 9 is marked as excluded.
Pressure distributions from my report at 60% fan setting, using the supplied upper/lower labels. The coefficient is referenced to room pressure, rather than a confirmed tunnel-static pressure. Negative values are plotted upwards. Tap 9 is shown for context and excluded from the integrated traces.
Open full-size pressure plot

A result that needed checking.

Using the supplied surface labels gave negative lift through the main loading range. I retained that signed result and also tested the effect of interchanging the upper and lower labels. The plot below shows that conditional interpretation.

Conditional sectional lift curves at three fan settings, assuming interchanged upper and lower labels. Measured peaks are 0.817 at 13.1 degrees for 30%, 1.210 at 14.1 degrees for 60%, and 1.278 at 19.0 degrees for 90%. An SD7003 reference curve is shown for comparison.
Conditional lift curves from the three sweeps. The marked peaks are sampled maxima, rather than independently confirmed stall angles. The SD7003 reference is from Selig et al., Summary of Low-Speed Airfoil Data, Vol. 1 (1995), Fig. 4.122, p. 208; geometry and test conditions differ.
Open full-size lift plot
Observed peaks under the conditional surface assignment
Fan settingPeak angleConditional CLOriginal signed CL
30%13.1°0.817−0.817
60%14.1°1.210−1.210
90%19.0°1.278−1.278

Small processing choices mattered.

At 60% fan setting and 14.1° incidence, I compared the baseline calculation with two alternative treatments. These changes in lift coefficient show why the method needs to be documented alongside the result.

0.133Change in lift coefficient magnitude

Reinstating tap 9's recorded zero instead of excluding the anomalous channel.

0.024Change in lift coefficient

Extending the nearest pressure difference to the chord ends instead of closing it to zero.

What I can conclude, and what comes next.

The study identified changes in loading and rollovers in the sampled lift curves. It also showed that a useful engineering result needs an explicit account of the data quality and assumptions behind it. The available evidence does not yet support a confident low-speed UAV suitability claim.

The next checks I would prioritise

  • Confirm the physical mounting, pressure-tap surface assignment and incidence convention.
  • Repeat the sweeps, with finer angle increments around each observed maximum.
  • Compare the pressure-based lift estimate with an independent force-balance measurement.
  • Assess finite-wing lift and drag before making an airframe-level recommendation.

Based on my November 2026 university laboratory report and analysis. The plots are reproduced from that report; the sign-convention and measurement limitations are retained here. The wider experimental interpretation is still being refined.

Explore all projectsDiscuss my work