Experimental aerodynamics · November 2026
From pressure
readings to lift.
An AF1300 wind tunnel study using 63 pressure datasets to estimate sectional lift, investigate changes in loading and understand how measurement choices affect the conclusion.
- My contribution
- Data processing, integration and interpretation
- Tools & methods
- Excel · pressure coefficients · trapezoidal integration
- Context
- University of Hertfordshire
Fluid Mechanics laboratory

The engineering question
What can the pressure data tell us?
The task was to turn surface pressure measurements into pressure distributions and sectional lift estimates, then assess what those results could say about a small UAV application. The available workbook contained 21 pressure records at each of three fan settings: 30%, 60% and 90%.
The analysis also needed to account for imperfect data. One channel was recorded as zero, the tunnel-static pressure offset was unavailable, and the supplied surface labels produced an unexpected lift sign.
My analysis workflow
Make the calculation traceable.
Check the measurements
I matched pressure columns to the supplied tap positions, normalised the chord stations and investigated tap 9, which was zero wherever recorded.
Calculate the loading
I normalised the pressure readings by dynamic pressure, interpolated both surfaces onto shared chord stations and calculated the pressure difference.
ΔCp = Cp,lower − Cp,upper
Integrate and challenge
I used trapezoidal integration and an incidence projection to estimate sectional lift. I then checked how the tap treatment, chord-end assumptions and surface convention changed the result.
Evidence from the analysis
A change in the pressure distribution.
At the 60% fan setting, the room-referenced coefficient at tap 2 changed from −5.99 at 14.1° to −2.65 at 16.1°. The reduction in suction and the flatter trace are consistent with a change in loading or separation. Without flow visualisation, they do not locate separation directly.

A result that needed checking.
Using the supplied surface labels gave negative lift through the main loading range. I retained that signed result and also tested the effect of interchanging the upper and lower labels. The plot below shows that conditional interpretation.

| Fan setting | Peak angle | Conditional CL | Original signed CL |
|---|---|---|---|
| 30% | 13.1° | 0.817 | −0.817 |
| 60% | 14.1° | 1.210 | −1.210 |
| 90% | 19.0° | 1.278 | −1.278 |
Sensitivity checks
Small processing choices mattered.
At 60% fan setting and 14.1° incidence, I compared the baseline calculation with two alternative treatments. These changes in lift coefficient show why the method needs to be documented alongside the result.
Reinstating tap 9's recorded zero instead of excluding the anomalous channel.
Extending the nearest pressure difference to the chord ends instead of closing it to zero.
Engineering judgement
What I can conclude, and what comes next.
The study identified changes in loading and rollovers in the sampled lift curves. It also showed that a useful engineering result needs an explicit account of the data quality and assumptions behind it. The available evidence does not yet support a confident low-speed UAV suitability claim.
The next checks I would prioritise
- Confirm the physical mounting, pressure-tap surface assignment and incidence convention.
- Repeat the sweeps, with finer angle increments around each observed maximum.
- Compare the pressure-based lift estimate with an independent force-balance measurement.
- Assess finite-wing lift and drag before making an airframe-level recommendation.
Based on my November 2026 university laboratory report and analysis. The plots are reproduced from that report; the sign-convention and measurement limitations are retained here. The wider experimental interpretation is still being refined.